Analytical system |
Fully automated, random-access clinical
chemistry system with STAT capability
|
|
Analytical principle |
Spectrophotometry and potentiometry
|
|
Analytical types |
Endpoint, rate, fixed point and indirect
ISE |
|
Analytical methods |
Colorimetry, turbidimetry, latex
agglutination, homogeneous EIA, indirect
ISE |
|
Simultaneously processed analytes
|
60 photometric tests + 3 ISE |
|
Throughput |
800 photometric tests/hour; up to 1,200
with ISE |
|
Sample types |
Serum, urine, whole blood (HbA1c), other
1, other 2 |
|
Sample feeder |
Racks with 10 samples each (bar codes on
primary tubes and on racks); capacity of
150 samples; continuous loading |
|
Sample tubes |
In primary and secondary tubes; diameter
between 11.5 and 16.5 mm; height between
55 and 102 mm |
|
STAT samples |
Up to 22 positions for STAT samples,
bar-coded primary tubes |
|
Sample volume |
1–25 μL in 0.1 μL increments (1–25 μL
for repeats) |
|
Reagent supply |
60 positions for R1, 48 positions for
R2; (refrigerated 4–12 °C), handling of
3-shot reagents |
|
Reagent volume |
R1: 15–250 μL; R2: 15–250 μL; (in 1 μL
increments) |
|
Total reaction volume |
120–425 μL |
|
Reaction cuvette |
Quartz cuvettes |
|
Reaction time |
Up to 8 minutes, 40 seconds |
|
Reaction temperature |
37 °C |
|
Mixing method |
With rotating paddles after dispensing
sample and reagent |
|
Photometry system
|
Direct assay through the reaction
cuvette (0 – 3.0 OD) mono and
bichromatic measurements possible |
|
Wavelength |
13 different wavelengths between 340 –
800 nm |
|
Cuvette cleaning |
Comprehensive cleaning with detergents
|
|
Calibration |
Autocalibration, cooled calibrator
positions; master calibration
established by two-dimensional bar code
of the reagent bottle (>3-point
calibration) |
|
Quality control |
Auto QC, cooled QC positions
|
|
Test requisition |
Individual and profile test requisition
via on line, mouse, functions keys or
touch screen |
|
Safety |
Clot detection and crash prevention for
sample and reagent dispenser
|
|
Online
|
Full uni- and bidirectional
communication possible |
|
Software |
Windows XP® |
|
Dimensions (W x H x D) mm
|
ANL 1,950 x 1,280 x 1,000 |
|
Power supply |
200 V; 208 V; 220 V; 230 V; 240 V; 50
Hz; 60 Hz/3.8 KVA |