OLYMPUS AU5200 CHEMISTRY IMMUNO ANALYZER
 

Alternative Biomedical Solutions sells a complete line of Quality Refurbished Olympus Chemistry Immuno Systems.

When you purchase from ABS you get:

- Quality Refurbished Systems at Significant 

   Savings

- Installation and onsite Operator Training

- Warranty – 12 months parts, labor & travel

- Technical Support

- Onsite Response – 24 to 48 hour

- Options – 24/7 and Business Hours

Analytical System

Discrete, twin reaction lines

Analytical method

End point assay, rate assay, fixed assay.

Simultaneous analysis items

16, 24, 32

Max processing capacity

7,920 chemistry results/hour (24 chemistries x 330 samples/hour).

Sample feeder

Rack system with a capacity of 10 samples per rack, with bar-coded sample readout capability. Accommodates 300 samples.

Sample vessel

14mm x 55mm(L) glass or plastic 13—16.5mmx55—102mm(L) primary tubes may also be used.

Emergency Samples

Interruptive analysis possible by loading emergency sample in the red rack.

Repeat run samples

Repeat run is possible by loading repeat run samples in the orange rack.

Sample volume

3—15ul in 1ul increments (1—15ul for repeat run). 4-test split dispensing.

Reagent storage

Refrigerated

Reagent Volume

1st reagent: 50—450ul in 1ul increments                                2nd reagent: 50—350ul in 1ul increments                                 2nd reagent is dispensed 3.6 minutes after sample is dispensed

Applicable reagents Commercially available reagents
Reaction line Twin reaction lines (turntable). Dry bath incubation method.
Reaction time 8 minutes and 31 seconds
Reaction temperature 37°C
Mixing method Rotating action from the stirring bars after dispensing the sample and after dispensing the second reagent.
Photometry System Direct photometry in reaction cuvettes. Required reaction mixture volume: 250ul, light path: 6mm. One or two-wavelength photometry with the diffraction grating.
Cuvette washing Washing and drying within the glass cuvette wheel
Calibration curve selection

Linear and sectional lines

Automatic: 5 points max.; Manual: 7 points max.

Quality Control By loading quality control samples in the green rack (3 types for each test, total of 8 samples types). Daily and day-to-day mean (X), range ®, standard deviation (SD) and coefficient of variation (CV) and demographics. Alarm for exceeding control limit.
Data processing Test ratio calculations, sample blank correction, and correlatire correction; normal, panic, dynamic and repeat run range judgment; reagent absorbance and reaction mixture absorbance check; abnormal value, pending list and repeat run wertesheet output.
Test item selection

Single or/and panel                                   

99 different panel definable                                

Requisition of 4,000 routine and 200 emergency samples possible.

Input/output Keyboard entry and on-line requisition. CRT, high-speed and online
Water supply/drainage

Automatic supply of deionized water  (30L/unit hr.)Drainage outlet not higher than 100mm above the floor level

 

Ambient Conditions

temperature: 15--30°C, within +- 2°C fluctuation during measurement, Relative humidity: 40—80% (non-condensing atmosphere).

   

Olympus, Roche, Hitachi Service and maintenance

   Reagents

   Distribution Info

   Purchase Info

   Our Company

   Customer Login

General Lab Supplies

  Contact Us:

  ABS

  2412 Arbuckle Court

  Dallas, TX 75229

  Phone: (972) 241-1388

  Toll Free: (866) 895-1388

  Fax:     (972) 241-1480

  sales@absbiomedical.com

 

     866-895-1388  - International & Domestic Distributors wanted.