Alternative Biomedical Solutions
sells a complete line of
Quality
Refurbished Olympus Chemistry Immuno
Systems.
When you
purchase from ABS you get:
-
Quality Refurbished Systems at
Significant
Savings
-
Installation and onsite Operator
Training
-
Warranty – 12 months parts, labor &
travel
- Technical Support
-
Onsite Response – 24 to 48 hour
-
Options – 24/7 and Business Hours
|
|
Analytical system
|
Fully automated, for
routine, STAT, urine and homogeneous
Immuno Assays |
|
Analytical methods
|
Clinical chemistry and
immunological parameters. End point,
kinetic assays, fixed-time-kinetics,
optionally ISE |
|
Simultaneously processed
analytes |
Up to 48 photometric
tests + 3 ISE |
|
Throughput
|
Up to 1,600 photometric
tests/hour; ISE: 270 samples /hour
|
|
Sample feeder
|
Racks with 10 samples
each (bar-codes on primary tubes and on
racks); capacity of 300 samples;
continuous loading |
|
Sample tubes
|
In primary and secondary
tubes; diameter from 11.5 to 16 mm;
height from 55 to 102 mm
|
|
STAT samples
|
Up to 22 positions for
STAT samples, bar-coded primary tubes
|
|
Sample volume
|
1.6 – 25 µl in 0.1 µl
steps (1 µl for repeats)
|
|
Reagent supply
|
Refrigerated (4 °C – 12
°C); 48 positions for R1; 48 positions
for R2 |
|
Reagent volume
|
1. reagent: 15 – 250 µl;
2. reagent: 15 – 250 µl
|
|
Total reaction volume
|
120– 400 µl
|
|
Reaction cuvette
|
Quartz cuvettes
|
|
Reaction time
|
Up to 8 minutes, 22
seconds |
|
Reaction temperature
|
37 °C; Mixing method With
rotating paddles after dispensing sample
and reagent |
|
Photometry system
|
Direct assay through the
reaction cuvette (0 – 2.5 OD) mono-,
bichromatic measurements possible
|
|
Wave length
|
13 different wave lengths
between 340 – 800 nm |
|
Cuvette cleaning
|
Comprehensive cleaning
with detergents |
|
Calibration
|
Linear and non linear
(linear interpolation), refrigerated
calibrator positions |
|
Data processing
|
Calculated parameters,
blank value correction and correlation.
Definition of normal value range,
measuring range, pathological values and
repeats. Quality controls, printout of
abnormal values, pending sample work
list and repeat run sample list
|
|
Test requisition
|
Individual and profile
test requisition via on-line, mouse,
function keys or optional touch screen
|
|
Safety
|
Clot detection and crash
prevention for sample and reagent
dispenser |
|
On-line
|
Full uni- and
bidirectional communication possible
|
|
Software
|
Windows-NT®; Modem
capability |
|
Dimensions (W x H x D) mm
|
ANL: 2,000 x 1,000 x 840;
DPR: 700 x 1,430 x 700
|